WARNING
Storing and Drying Requirements for ADVANCER® Kiln Shelves
ADVANCER® Kiln Shelves (silicon nitride-bonded silicon carbide) are refractory components and should be stored in a dry, enclosed area.
ADVANCER® refractory components exposed to prolonged moisture penetration may result in catastrophic failure (i.e., steam explosion) during any rapid heat-up process of the kiln. Accordingly, DO NOT expose ADVANCER® refractory components to any prolonged moisture source including rain, snow, condensation, etc.
The application of kiln washes and coatings on ADVANCER® refractory components is an acceptable practice and is not considered a source of prolonged moisture.
If any ADVANCER® refractory components are exposed to prolonged moisture, the product must be completely dried before it is used at temperatures exceeding 212ºF (100ºC). As a general guideline for the drying of ADVANCER® refractory components, the product must be held slightly above the boiling point of water for a sufficient length of time to expel any moisture and as much steam as possible. The following is a recommended drying cycle for ADVANCER® refractory components exposed to prolonged moisture.
Recommended Dry Out Procedure
Heat from ambient to 210ºF (99ºC) at a rate of 50ºF (28ºC)/hour.
Slow heating rate to 25ºF (14ºC)/hour to 230ºF (110ºC).
Hold at 230ºF (110ºC) for 12 hours ensuring that the entire load has reached the soak temperature before the timing of the soak has begun.
Raise temperature to 350-500ºF (177-260ºC) at a rate of 100ºF (56oC)/hour.
Hold soak temperature for 16 hours ensuring that the entire load has reached the soak temperature before the timing of the soak has begun.
Cool naturally/slowly by turning off the heating source.
Call us with any questions regarding moisture-related issues with ADVANCER® refractory components.
Reviews
There are no reviews yet.